Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberELE09-00388
StatusFinaled
Name WILLIAM HART
Site Address 2402 W HILL RD
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
ELE-Aging Inspection4/10/20134/10/20134/11/2013 DONE
DetailsRock A. Hudson
Stopped by and met home owner. original permit for Hot tub and service on garage. Hot tub has been removed, service final ok
Final4/11/20134/11/20134/11/2013PPASS
DetailsRock A. Hudson
Hot tub has been removed and service on garage final ok
ELE-Aging Inspection1/9/20131/9/20131/9/2013 DONE
DetailsRock A. Hudson
Phone number listed no longer valid
ELE-Aging Inspection10/10/201210/10/201210/10/2012 DONE
DetailsRock A. Hudson
called no answer
ELE-Aging Inspection7/11/20127/11/20127/17/2012 PASS
DetailsDaryl DeGrange
no activity
ELE-Aging Inspection3/23/20123/23/20123/28/2012 PASS
DetailsDaryl DeGrange
still under construction
ELE-Aging Inspection12/23/201112/23/201112/29/2011 DONE
DetailsDaryl DeGrange
No activity, but still under construction
ELE-Aging Inspection8/15/20118/15/20118/15/2011 DONE
DetailsDaryl DeGrange
No activity No phone number
ELE-Aging Inspection4/27/20114/27/20114/28/2011 DONE
DetailsDaryl DeGrange
no activity-no contact phone number, left card in door for second time, no responce.
ELE-Aging Inspection2/25/20112/25/20113/4/2011 DONE
DetailsDaryl DeGrange
job still under construction stop by 3/04/11
ELE-Aging Inspection12/16/201012/16/201012/22/2010 DONE
DetailsDaryl DeGrange
usc no ativty
ELE-Aging Inspection10/5/201010/5/201010/5/2010 DONE
DetailsBob Reichert
suc
Final3/16/20093/17/20093/17/2009ANR
DetailsPat Lass
Will Phone #: ###-####
this should have been for a service inspection
Permanent Service3/17/20093/17/20093/17/2009APASS
DetailsPat Lass
Will Phone #: ###-####
P/S O/H N Ok
Permanent Service3/16/20093/16/20093/16/2009PFAIL
DetailsPat Lass
william Phone #: ###-####
remove mc sheath from GEC. drive groundrods flush install plastic romex connector on GEC. #6 neutral to be white for entire length recep to be 6 ft from hot tub.
Conference3/9/20093/12/20093/12/2009ADONE
DetailsMike Kinnear
William ###-#### went over service mast 2inch imc or rigid, 2 ground rods, & metal bonding for hot tub. also owner needs to get permit for hot tub. note no resc permit in project