Final | 12/28/2009 | 12/28/2009 | 12/28/2009 | P | PASS |
Doug A Poedy
|
|
|
hawk Phone #: ###-####
|
DOC - Permit Finaled | 12/28/2009 | 12/28/2009 | 12/28/2009 | P | PASS |
Doug A Poedy
|
|
|
|
Final | 11/20/2009 | 11/20/2009 | 11/20/2009 | P | CANC |
Doug A Poedy
|
|
|
Hawk Phone #: ###-####. Rescheduling
|
Final | 11/13/2009 | 11/13/2009 | 11/13/2009 | P | FAIL |
Doug A Poedy
|
|
|
HAWK Phone #: ###-####. NEC 210.8 A2@3 Garage gfci, Outdoor gfci. Install switch for fan upstairs.
|
Electrical Rough-In | 7/7/2009 | 7/10/2009 | 7/10/2009 | A | PASS |
Doug A Poedy
|
|
|
Hawk Phone #: ###-####. Ok to cover
|
Electrical Rough-In | 6/25/2009 | 6/26/2009 | 6/26/2009 | A | NR |
Mike Kinnear
|
|
|
hawk Phone #: ###-#### t/w owner missing nail plates, cables not stapled with in 8inchs of the box, 111/4 stapling. he wanted t/w 370.
|
Electrical Rough-In | 6/11/2009 | 6/12/2009 | 6/12/2009 | P | CANC |
Bob Reichert
|
|
|
hawk Phone #: ###-#### see conference
|
Conference | 6/12/2009 | 6/12/2009 | 6/12/2009 | P | DONE |
Bob Reichert
|
|
|
hawk Phone #: ###-#### met owner, talked about stapling romex within 8" of all boxes,mount box to framing member, add receptacles to bedrooms in 2' wall spaces, add smoke detectors so wiring can be inspected, ground metal boxes,staple mc cable, owner will do work then call dor inspection
|
Conference | 5/5/2009 | 5/6/2009 | 5/6/2009 | A | PART |
Jack Frank
|
|
|
Hawk- call to set up time to meet Phone #: ###-#### called answered owner's questions
|
Conference | 4/27/2009 | 4/30/2009 | 4/30/2009 | A | PART |
Pat Lass
|
|
|
hawk Phone #: ###-#### talked about cable in raceway
|
Conference | 4/17/2009 | 4/17/2009 | 4/17/2009 | P | PART |
Pat Lass
|
|
|
Hawk Phone #: ###-#### talked about general requirements
|