Final | 7/17/2009 | 7/20/2009 | 7/20/2009 | P | CANC |
Doug A Poedy
|
|
|
Eric Phone #: ###-####. already finaled.
|
Final | 7/17/2009 | 7/17/2009 | 7/17/2009 | P | PASS |
Doug A Poedy
|
|
|
eric Phone #: ###-####. Ok final. No esc permit.
|
Final | 7/16/2009 | 7/17/2009 | 7/17/2009 | A | FAIL |
Doug A Poedy
|
|
|
Eric Phone #: ###-####. NEC 210.8 (A)(3) SHALL HAVE GROUND FAULT PROTECTION OUTDOORS.
|
Electrical Rough-In | 5/20/2009 | 5/20/2009 | 5/20/2009 | P | PASS |
Bob Reichert
|
|
|
eric Phone #: ###-#### called owner, ric ok, check outlet and switch for grounds at final, no esc this project
|
Electrical Rough-In | 5/19/2009 | 5/19/2009 | 5/19/2009 | P | FAIL |
Bob Reichert
|
|
|
eric - please call 1/2 hr prior Phone #: ###-#### met owner, gave corrections, NEC 210.52 (A) sjall add 2 receptacles for wall space, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, no esc this project
|
Electrical Rough-In | 5/12/2009 | 5/12/2009 | 5/12/2009 | P | CANC |
Bob Reichert
|
|
|
Russ Phone #: ###-#### owner not present, told builder that owner must be there to review corrections and that owner has to call for inspection, no esc this project
|
Conference | 5/8/2009 | 5/11/2009 | 5/11/2009 | A | DONE |
Bob Reichert
|
|
|
Eric ###-#### talked with owner about doing job per NEC, free conductor length, outlet spacing, make-up, 1 1/4", when call for ri, be on-site, no esc this project
|