Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE09-00801
StatusFinaled
Name BONNIE L EISEN
Site Address 914 W PUEBLO ST
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/17/20097/20/20097/20/2009PCANC
DetailsDoug A Poedy
Eric Phone #: ###-####. already finaled.
Final7/17/20097/17/20097/17/2009PPASS
DetailsDoug A Poedy
eric Phone #: ###-####. Ok final. No esc permit.
Final7/16/20097/17/20097/17/2009AFAIL
DetailsDoug A Poedy
Eric Phone #: ###-####. NEC 210.8 (A)(3) SHALL HAVE GROUND FAULT PROTECTION OUTDOORS.
Electrical Rough-In5/20/20095/20/20095/20/2009PPASS
DetailsBob Reichert
eric Phone #: ###-#### called owner, ric ok, check outlet and switch for grounds at final, no esc this project
Electrical Rough-In5/19/20095/19/20095/19/2009PFAIL
DetailsBob Reichert
eric - please call 1/2 hr prior Phone #: ###-#### met owner, gave corrections, NEC 210.52 (A) sjall add 2 receptacles for wall space, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, no esc this project
Electrical Rough-In5/12/20095/12/20095/12/2009PCANC
DetailsBob Reichert
Russ Phone #: ###-#### owner not present, told builder that owner must be there to review corrections and that owner has to call for inspection, no esc this project
Conference5/8/20095/11/20095/11/2009ADONE
DetailsBob Reichert
Eric ###-#### talked with owner about doing job per NEC, free conductor length, outlet spacing, make-up, 1 1/4", when call for ri, be on-site, no esc this project