Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberELE09-00910
StatusFinaled
Name ELECTRIC SERVICE & CONTRACT CO
Site Address 3920 W HILLCREST DR
Project Name 
Customer Number2943
ePlanReview 
Description
Electrical Permit - Alteration: Upgrade existing panel to 200 amps. Install light fixture, recept, baseboard heater in shed.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/12/200910/13/200910/13/2009APASS
DetailsBob Reichert
Scott Johnson Phone #: ###-#### Internet Inspection Request from: Dave Friend ok to final, no esc this project
Final8/12/20098/14/20098/14/2009ACANC
DetailsBob Reichert
Contact person is Scott Johnson
Phone #: ###-#### Internet Inspection Request from: Dave Friend wrong type request, see rip
Rough-In Permanent Service8/14/20098/14/20098/14/2009APASS
DetailsBob Reichert
Contact person is Scott Johnson
Phone #: ###-#### Internet Inspection Request from: Dave Friend called office to put in correct information for permit, corrections made, u/g house to shed ok to cover, ri shed ok to cover, p/s o/h rec ok, no esc this project
Electrical Rough-In8/11/20098/12/20098/12/2009ACANC
DetailsBob Reichert
Contact person is Scott Johnson Phone #: ###-#### Internet Inspection Request from: Dave Friend see conference
Conference8/12/20098/12/20098/12/2009ADONE
DetailsBob Reichert
Contact person is Scott Johnson Phone #: ###-#### Internet Inspection Request from: Dave Friend met contractor, told to change permit to 3 rooms, add service, showed contractor where he was missing wall space and 1 1/4", checked box fill, will fix all and recall for inspection, no esc this project
Electrical Rough-In8/10/20098/11/20098/11/2009PFAIL
DetailsBob Reichert
Have you inspected new service? Phone #: ###-#### Internet Inspection Request from: Dave Friend corrections not made, called, phone not being answered, goes to busy signal,can't leave message, u/g covered, 1 1/4" not fixed, romex connector on gec(bare copper), outlet spacing not correct, can't see grounding,
Electrical Rough-In7/16/20097/17/20097/17/2009PCANC
DetailsBob Reichert
Call Ray for inspection results Phone #: ###-#### Internet Inspection Request from: Dave Friend called contractor, told that without bld and plumbing permits, that if 370 came to inspect, would issue stop work order and fee due charges, the contractor asked to cancel the request until they could talk with the owner of the property, no esc this project
Electrical Rough-In7/15/20097/16/20097/16/2009PFAIL
DetailsBob Reichert
Call Ray for access and description of
work to be inspected at ###-#### Internet Inspection Request from: Dave Friend called contractor, and structural, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(A) shall provide receptacle spacing per code, 225.36 disconnect shall be suitable for service equipment, 250.32 shall provide grounding electrode system, BCC all underground shall be inspected before cover, approved set of plans shall be on job, all make-up shall be done, shall not cover any wiring befor inspection, shall obtain building and plumbing permits, no esc this project