Final | 9/14/2009 | 9/15/2009 | 9/15/2009 | A | PASS |
Doug A Poedy
|
|
|
Thank you! Phone #: ###-#### Internet Inspection Request from: Adam Staigle. Ok final.
|
Final | 9/13/2009 | 9/14/2009 | 9/14/2009 | P | FAIL |
Doug A Poedy
|
|
|
Final for back covered deck. Thank You! Phone #: ###-#### Internet Inspection Request from: Adam Staigle. NEC 340.10(4) Uses permitted. Using UF cable as non metalic sheathed cable. Refers to article 334, Must be concealed.
|
Electrical Rough-In | 8/16/2009 | 8/17/2009 | 8/17/2009 | A | PASS |
Doug A Poedy
|
|
|
Cover inspection for covered back deck. (6) Can lights and (2) light boxes will be "boxed in" otherwise framing members to remain exposed. Wiring method is UF cable laid on the roof-top. UF cable is plated at all ceiling joists. Roofing material will be 2" of insulated foam carefully nailed in place in 2 foot sections with a white refelective membrane glued over the top. Thank You! Phone #: ###-#### Internet Inspection Request from: Adam Staigle. Ok cover.
|