Final | 12/14/2009 | 12/15/2009 | 12/15/2009 | A | PASS |
Doug A Poedy
|
|
|
Earnie please call 30 min before going out Phone #: ###-####
|
DOC - Permit Finaled | 12/15/2009 | 12/15/2009 | 12/15/2009 | P | PASS |
Doug A Poedy
|
|
|
|
Permanent Service | 12/2/2009 | 12/2/2009 | 12/2/2009 | P | PASS |
Doug A Poedy
|
|
|
Mike Phone #: ###-####. P/S O/H Reconnect ok.
|
Electrical Rough-In | 10/6/2009 | 10/7/2009 | 10/7/2009 | A | PASS |
Doug A Poedy
|
|
|
mike Phone #: ###-####. ok to cover.
|
Electrical Rough-In | 10/2/2009 | 10/5/2009 | 10/5/2009 | A | FAIL |
Jack Frank
|
|
|
please call 10 min ahead of time to meet//Ernie ###-#### corr called 210.52(A&B) outlet for wall space top of stairs in west wall of kit area, 300.14 free length all boxes, 314.16 box fill old box in din rm, 300.4 11/4" cables parallel 110.3(B) and 422.16(D) remove hood from dw circuit, if cord and plug connected shall be on it's own circuit
|