Final | 2/16/2010 | 2/16/2010 | 2/16/2010 | P | PASS |
Bob Reichert
|
|
|
dan Phone #: ###-#### ok to final, signed structural card, no esc this project
|
Electrical Rough-In | 1/22/2010 | 1/22/2010 | 1/22/2010 | P | PART |
Bob Reichert
|
|
|
dan - late afternoon please Phone #: ###-#### 2nd bath only ok to cover, no esc this project
|
Electrical Rough-In | 1/11/2010 | 1/11/2010 | 1/11/2010 | P | PART |
Bob Reichert
|
|
|
Ceiling inspection Dan ###-#### ok to cover ceilings, left correction notice for rootop, NEC 210.63 shall provide weather proof and gfci receptacle within 25' of exhaust fan, BCC no violations shall be retained, no esc this project
|
Electrical Rough-In | 12/2/2009 | 12/3/2009 | 12/3/2009 | P | PASS |
Bob Reichert
|
|
|
Dan-please call at least 20 mins prior to inspection so he can meet ya there Phone #: ###-#### walls only ok to cover, left correction notice NEC 210.4(B) multiwire circuits shall be provided with simultaneous disconnect for all branch circuits where circuit originates, BCC no violations shall be retained- crawl space
|