Final | 1/27/2010 | 1/28/2010 | 1/28/2010 | A | PASS |
Doug A Poedy
|
|
|
Trench inspection.Call Rob for access. ###-#### Phone #: ###-#### Internet Inspection Request from: Craig Korell
|
Electrical Rough-In | 1/27/2010 | 1/28/2010 | 1/28/2010 | A | PASS |
Doug A Poedy
|
|
|
Trench inspection.Call Rob for access. ###-#### Phone #: ###-#### Internet Inspection Request from: Craig Korell
|
Electrical Rough-In | 12/17/2009 | 12/18/2009 | 12/18/2009 | A | FAIL |
Bob Reichert
|
|
|
Need trench inspection. All work is behind house. No gates. No dogs. Very muddy. Phone #: ###-#### Internet Inspection Request from: Craig Korell called, left correction notice, NEC 300.5 raceways shall be 18" deep from top of raceway to finished grade, 310.15(B)(1)(2)(b) shall maintain spacing between raceways, no esc this project
|