Permit Information
Permit NumberELE10-00215
StatusFinaled
Name C H ELECTRIC
Site Address 1617 S LONGMONT AVE
Project Nameduplex
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/26/20103/26/20103/26/2010PPASS
DetailsBob Reichert
key above side door Inspection requested from web by: Chris Berthelot Phone #: ###-#### corrections made, ok to final
Final3/25/20103/26/20103/26/2010ANH
DetailsBob Reichert
Inspection requested from web by: Chris Berthelot Phone #: ###-#### called, left message, fee due, left card
Final3/25/20103/25/20103/25/2010PFAIL
DetailsJack Frank
Inspection requested from web by: Chris Berthelot Phone #: ###-#### correction, 410.2&16 needs required clearence for closet fixtures and install shelves in closets called
Electrical Rough-In2/22/20102/22/20102/22/2010PPASS
DetailsBob Reichert
Chris- garage Phone #: ###-#### ric ok garage only
Rough-In Permanent Service2/8/20102/9/20102/9/2010APASS
DetailsBob Reichert
CHRIS Phone #: ###-#### corrections made, called for survey receptacle in dining room, and label service disconnects, ric ok, p/s u/g n ok
Electrical Rough-In2/5/20102/5/20102/8/2010PFAIL
DetailsBob Reichert
Chris-Late this afternoon please Phone #: ###-#### called, left message, left correction notice, NECn300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 314.20 boxes shall be flush with finished surface on outside, BCC shall install boxes and panel before cover, shall see u/g before cover, NOTE: corrections shall be msde in 5 working days or further action will be taken