Final | 4/19/2010 | 4/19/2010 | 4/19/2010 | A | PASS |
Bob Reichert
|
|
|
Inspection requested from web by: Lee VanSchoiack Phone #: ###-#### called, ok to final
|
Electrical Rough-In | 4/2/2010 | 4/2/2010 | 4/2/2010 | P | PASS |
Bob Reichert
|
|
|
pool lights potting compound Inspection requested from web by: Lee VanSchoiack Phone #: ###-#### potting ok
|
Electrical Rough-In | 3/23/2010 | 3/23/2010 | 3/23/2010 | A | PASS |
Bob Reichert
|
|
|
ug conduit Inspection requested from web by: Lee VanSchoiack Phone #: ###-#### corrections made, ok to cover u/g
|
Electrical Rough-In | 3/19/2010 | 3/22/2010 | 3/22/2010 | A | FAIL |
Bob Reichert
|
|
|
ug conduit Inspection requested from web by: Lee VanSchoiack Phone #: ###-#### called, left correction notice, NEC 352.26 there shall not be over 360 degree total bend in pvc, 680.10 minimum burial depth shall be 18" within 5' of pool, NOTE: corrections shall be made within 5 working days or further action will be taken
|
Electrical Rough-In | 3/16/2010 | 3/17/2010 | 3/17/2010 | A | PASS |
Bob Reichert
|
|
|
pool bonding Inspection requested from web by: Lee VanSchoiack Phone #: ###-#### pool bond only ok, no u/g done
|