Final | 7/7/2010 | 7/8/2010 | 7/7/2010 | A | PASS |
Jack Frank
|
|
|
mike Phone #: ###-####
|
Rough-In Permanent Service | 6/11/2010 | 6/14/2010 | 6/14/2010 | P | PASS |
Doug A Poedy
|
|
|
MIKES CELL IS ###-####, ALSO DEAN SHOULD BE ON SITE WORKING. Inspection requested from web by: Jamie Winters. P/S U/G Connect ok.
|
Rough-In Permanent Service | 6/11/2010 | 6/11/2010 | 6/11/2010 | P | FAIL |
Jack Frank
|
|
|
Jamie''s cell is ###-#### Inspection requested from web by: Jamie Winters called stillneeds to terminate GEC at neutral (grounded) bus, not the equipment grounding bus
|
Rough-In Permanent Service | 6/9/2010 | 6/10/2010 | 6/10/2010 | A | FAIL |
Jack Frank
|
|
|
CORRECTIONS ARE MADE READY FOR REINSPECT. Inspection requested from web by: Mike TenHulzen Phone #: ###-#### grding at p/s not corrected called
|
Rough-In Permanent Service | 6/8/2010 | 6/9/2010 | 6/9/2010 | A | FAIL |
Jack Frank
|
|
|
The contact for this is Mike TenHulzen Inspection requested from web by: Jamie Winters Phone #: ###-#### met contr GEC shall terminate at neutral bus, also needs sq D bonding means and equip grd kit, x former grding shall be at X/O terminal not the enclosure
|
Rough-In Permanent Service | 5/18/2010 | 5/19/2010 | 5/19/2010 | A | FAIL |
Bob Reichert
|
|
|
ROUGH-IN PERMANENT SERVICE READY IF QUESTIONS PLEASE CALL MIKE AT ###-####. Inspection requested from web by: Mike TenHulzen Phone #: ###-#### called contractor, told that NEC 250.24 shall connect gec to grounded concuctor at servive disconnect, shall provide meter, 310.4(B) parallel conductors shall be same length, check wireway under gear for correct size
|
Electrical Rough-In | 4/28/2010 | 4/28/2010 | 4/28/2010 | P | PASS |
Doug A Poedy
|
|
|
mike - ###-####. Ok to cover underground and attic.
|
Electrical Rough-In | 3/29/2010 | 3/30/2010 | 3/30/2010 | A | PART |
Jack Frank
|
|
|
UG ready in building only outside building ready later if problems please call Mike at ###-####. On a seperate note there seems to a problem with online service I have reenter a password everytime I use the service can someone please contact me at ###-####. Inspection requested from web by: Mike TenHulzen Phone #: ###-#### u/g inside ok
|
Final | 3/26/2010 | 3/29/2010 | 3/29/2010 | A | CANC |
Bob Reichert
|
|
|
UG in pump station inspection UG for remaining work will be ready for inspection Tuesday or Wednesday. If there are any questions or problems please Mike at ###-#### Inspection requested from web by: Mike TenHulzen Phone #: ###-#### wrong type request, see ri
|
Electrical Rough-In | 3/29/2010 | 3/29/2010 | 3/29/2010 | A | FAIL |
Bob Reichert
|
|
|
UG in pump station inspection UG for remaining work will be ready for inspection Tuesday or Wednesday. If there are any questions or problems please Mike at ###-#### Inspection requested from web by: Mike TenHulzen Phone #: ###-#### called, left correction notice, NEC 310.15(B)2(b) shall maintain conduit spacing
|