Final | 7/16/2010 | 7/16/2010 | 7/16/2010 | P | PASS |
Bob Reichert
|
|
|
terry - please call for access Phone #: ###-#### ok final
|
Rough-In Permanent Service | 5/14/2010 | 5/14/2010 | 5/14/2010 | P | PASS |
Bob Reichert
|
|
|
Inspection requested from web by: Stephen Kren Phone #: ###-#### corrections made, ric ok, p/s u/g n ok
|
Rough-In Permanent Service | 5/13/2010 | 5/14/2010 | 5/14/2010 | A | FAIL |
Bob Reichert
|
|
|
Thanks, Terry W. Inspection requested from web by: Stephen Kren Phone #: ###-#### called, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, BCC shall provide boxes for wiring terminations, master bath, data, shall provide available fault current from ipco, NOTE corrections shall be made within 5 working days or further action will be taken
|