Final | 6/15/2010 | 6/15/2010 | 6/15/2010 | P | PASS |
Bob Reichert
|
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### ok to final
|
Rough-In Permanent Service | 5/12/2010 | 5/13/2010 | 5/13/2010 | A | PASS |
Bob Reichert
|
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### corrections made, ric ok, p/s u/g n ok
|
Rough-In Permanent Service | 5/11/2010 | 5/12/2010 | 5/12/2010 | P | FAIL |
Bob Reichert
|
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### called, left correction notice, NEC 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(E)(1) shall provide receptacle at rear of dwelling, 334.23 shall protect cables at attic access- up and down, Note corrections shall be made within 5 working days or further action will be taken
|