Final | 7/7/2010 | 7/7/2010 | 7/7/2010 | P | PASS |
Bob Reichert
|
|
|
Please call ###-#### - 20 mins. prior to arrival. Inspection requested from web by: John Edwards Phone #: ###-#### ok to final
|
Final | 6/8/2010 | 6/8/2010 | 6/8/2010 | P | CANC |
Bob Reichert
|
|
|
Please call Jimmy @ ###-#### prior to arrival - thanks Inspection requested from web by: John Edwards Phone #: ###-#### wrong type request, see ri
|
Electrical Rough-In | 6/8/2010 | 6/8/2010 | 6/8/2010 | P | PASS |
Bob Reichert
|
|
|
Please call Jimmy @ ###-#### prior to arrival - thanks Inspection requested from web by: John Edwards Phone #: ###-#### corrections made, ric ok
|
Rough-In Permanent Service | 6/7/2010 | 6/8/2010 | 6/8/2010 | A | NH |
Bob Reichert
|
|
|
Please call 20 min prior to arrival. Inspection requested from web by: John Edwards Phone #: ###-#### called, nh, left card, fee due
|
Rough-In Permanent Service | 6/4/2010 | 6/4/2010 | 6/7/2010 | P | FAIL |
Bob Reichert
|
|
|
Please call me 30 minutes prior to arrival so i can arrange entry. Inspection requested from web by: John Edwards Phone #: ###-#### met contractor, left correction notice, NEC 110.26 dedicated space shall be provided, 300.4 shall provide nailplates, 210.52(A)(1) shall provide outlet spacing in new walls Note: corrections sahll be made in 5 working days or further action will be taken
|