Permit Information
Permit NumberELE10-01593
StatusFinaled
Name RIVERSIDE ELECTRIC INC
Site Address 5821 N PARCHMENT AVE
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/31/20164/1/20164/1/2016APASS
DetailsRock A. Hudson
not sure on this permit i see its still active work was done months ago. if you have already final it sorry for the inconvenience. side gate is unlocked. thanks mike Phone #: ###-#### Inspection requested via web by michael hunt Final ok
ELE-Aging Inspection3/11/20163/11/20163/11/2016 PASS
DetailsRock A. Hudson
Owner refusing to respond.
ELE-Aging Inspection12/11/201512/11/201512/11/2015 DONE
DetailsRock A. Hudson
Owner refusing to respond
ELE-Aging Inspection9/11/20159/11/20159/11/2015 DONE
DetailsRock A. Hudson
Owner refusing to comply. Turning over to City Attorney
ELE-Aging Inspection6/12/20156/12/20156/19/2015 CANC
DetailsRock A. Hudson
Too busy
ELE-Aging Inspection3/13/20153/13/20153/13/2015 DONE
DetailsRock A. Hudson
Posted correction notice- This notice is to inform owner a open electrical permit exists on property for wiring to a swimming pool. We have notes from previous inspection of a violation which is GFCI protection for circuits serving pool. Please contact Riverside Electric ###-#### for final. Please do not delay. Future notificatins will have reinspction fees attached.
ELE-Aging Inspection12/12/201412/12/201412/17/2014 DONE
DetailsRock A. Hudson
Waiting on owner
ELE-Aging Inspection9/12/20149/12/20149/18/2014 DONE
DetailsDaryl DeGrange
Spoke with contractor, comfirmed he would schedule final inspection
ELE-Aging Inspection6/4/20146/4/20146/6/2014 FAIL
DetailsDaryl DeGrange
NEC 680.22(B) pool equipment 120 or 240 volt 15 and 20 ampere require GFCI protection
ELE-Aging Inspection3/5/20143/5/20143/13/2014 DONE
DetailsDaryl DeGrange
called contractor, left message
ELE-Aging Inspection12/4/201312/4/201312/11/2013 DONE
DetailsDaryl DeGrange
Left correction notice at front door
ELE-Aging Inspection7/29/20137/29/20137/30/2013 DONE
DetailsDaryl DeGrange
Electrical contractor trying to make contact with homeowner.
ELE-Aging Inspection4/18/20134/18/20134/23/2013 DONE
DetailsDaryl DeGrange
homeowner not responding
ELE-Aging Inspection1/17/20131/17/20131/17/2013 DONE
DetailsDaryl DeGrange
Elect. contractor will contacted homeowner for access
ELE-Aging Inspection10/18/201210/18/201210/18/2012 DONE
DetailsDaryl DeGrange
still under construction
ELE-Aging Inspection7/19/20127/19/20127/24/2012 CANC
DetailsJack Frank
ELE-Aging Inspection4/19/20124/19/20124/24/2012 DONE
DetailsJack Frank
ELE-Aging Inspection1/19/20121/19/20121/24/2012 DONE
DetailsJack Frank
ELE-Aging Inspection8/30/20118/30/20118/30/2011 DONE
DetailsJack Frank
ELE-Aging Inspection5/31/20115/31/20116/6/2011 DONE
DetailsJack Frank
wsuc
ELE-Aging Inspection2/17/20112/17/20112/22/2011 DONE
DetailsJack Frank
ELE-Aging Inspection12/16/201012/16/201012/22/2010 CANC
DetailsJack Frank
Electrical Rough-In7/29/20107/30/20107/30/2010APASS
DetailsJack Frank
Mike-Conduit and bonding inspection please Phone #: ###-####