Final | 12/8/2010 | 12/8/2010 | 12/8/2010 | P | PASS |
Daryl DeGrange
|
|
|
Contact: Shane Korte Phone #: ###-#### >> Inspection requested via web by Deb Gooden final ok
|
Final | 12/7/2010 | 12/8/2010 | 12/8/2010 | A | FAIL |
Daryl DeGrange
|
|
|
Contact: Shane Korte Phone #: ###-#### >> Inspection requested via web by Deb Gooden not ready hardwood floor company haed wired to dryer recptacle
|
Final | 12/7/2010 | 12/8/2010 | 12/7/2010 | P | CANC |
Daryl DeGrange
|
|
|
Contact: Shane Korte Phone #: ###-#### >> Inspection requested via web by Deb Gooden Inspection cancelled from web by: Deb Gooden
|
Permanent Service | 10/22/2010 | 10/22/2010 | 10/22/2010 | P | PASS |
Doug A Poedy
|
|
|
Contact: Shane Korte Phone #: ###-#### >> Inspection requested via web by Deb Gooden. P/S O/H Connect ok.
|
Electrical Rough-In | 10/5/2010 | 10/6/2010 | 10/6/2010 | A | PASS |
Bob Reichert
|
|
|
Contact: Shane Korte Phone #: ###-#### >> Inspection requested via web by Deb Gooden corrections made, ri ok
|
Electrical Rough-In | 9/28/2010 | 9/28/2010 | 9/28/2010 | P | FAIL |
Bob Reichert
|
|
|
Contact: Shane Korte Phone #: ###-#### >> Inspection requested via web by Deb Gooden called, wrong number, left correction notice, NEC 210.52(a)(1) no point along floor line shall be over 6' from outlet, 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing member, 334.30 shall staple nm cable within 12" of box or 8" if more than 1, 250.86 shall ground metal boxes
|
Electrical Rough-In | 9/17/2010 | 9/20/2010 | 9/20/2010 | A | PART |
Jack Frank
|
|
|
Contact Shane Korte Phone #: ###-#### >> Inspection requested via web by Shelli Daylong exterior walls and attic ok for insulation
|
Electrical Rough-In | 9/16/2010 | 9/17/2010 | 9/17/2010 | P | CANC |
Bob Reichert
|
|
|
Contact: Shane Korte - Late afternoon inspection if possible please Phone #: ###-#### >> Inspection requested via web by Deb Gooden yalked to electrician, needed several more hours before ready, will call for early Monday
|