Final | 2/7/2011 | 2/7/2011 | 2/7/2011 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by Zane Robertson ok final, signed card
|
Final | 2/4/2011 | 2/7/2011 | 2/7/2011 | A | PART |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by Zane Robertson ok cover ceiling, left correction notice, NEC 110.12(A) shall close unused openings, 210.8(B)(5) shall provide gfci protection for receptacles within 6' of sink, 362.30 shall strap ent within 3' of box
|
Final | 2/3/2011 | 2/3/2011 | 2/3/2011 | P | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by Zane Robertson called, left correction notice, NEC 725.5 shall remove abandoned lv cables, 314.23 shall support boxes, 300.11 shall secure boxes, cables,raceways, grid shall not support boxes or cables, 110.12(A) shall close unused openings, BCC shall call for ceiling inspection, no violations shall be retained
|
Electrical Rough-In | 12/30/2010 | 1/3/2011 | 1/3/2011 | P | PASS |
Daryl DeGrange
|
|
|
Rewired and added outlets for remodel Phone #: ###-#### >> Inspection requested via web by Zane Robertson ri ok
|