Final | 8/17/2012 | 8/20/2012 | 8/20/2012 | P | PASS |
Bob Reichert
|
|
|
Devon Phone #: ###-#### ok final
|
ELE-Aging Inspection | 8/9/2012 | 8/9/2012 | 8/10/2012 | | CANC |
Bob Reichert
|
|
|
|
Electrical Rough-In | 5/10/2012 | 5/11/2012 | 5/11/2012 | A | PASS |
Bob Reichert
|
|
|
Devon Phone #: ###-#### u/g house to garage ok cover
|
ELE-Aging Inspection | 5/8/2012 | 5/8/2012 | 5/10/2012 | | DONE |
Bob Reichert
|
|
|
still under construction
|
ELE-Aging Inspection | 2/7/2012 | 2/7/2012 | 2/7/2012 | | DONE |
Bob Reichert
|
|
|
still under construction
|
ELE-Aging Inspection | 11/1/2011 | 11/1/2011 | 11/1/2011 | | DONE |
Bob Reichert
|
|
|
still under construction
|
Permanent Service | 8/2/2011 | 8/2/2011 | 8/2/2011 | P | PASS |
Bob Reichert
|
|
|
call prior//Devon Phone #: ###-#### p/s o/h n ok
|
Electrical Rough-In | 7/13/2011 | 7/13/2011 | 7/13/2011 | P | PASS |
Bob Reichert
|
|
|
DEVON Phone #: ###-#### outside receptacles, panel closed ok
|
Electrical Rough-In | 5/31/2011 | 6/1/2011 | 6/1/2011 | P | PASS |
Bob Reichert
|
|
|
devon Phone #: ###-#### corrections as noted done, called, left message, shall add receptacle front and rear dwelling by final, also shall close openings in panel with correct closure plates
|
Electrical Rough-In | 5/25/2011 | 5/25/2011 | 5/25/2011 | P | FAIL |
Bob Reichert
|
|
|
Devon Phone #: ###-#### called, left correction notice, NEC 312.5 shall secure each cable to cabinet, 334.30 sahll secure nm within 12" of box, 312.5 all conductors entering cabinet shall have abrasion protection, 110.26 there shall not be piping in dedicated panel space, 250.53(G) upper end of ground rods shall be flush with grade, 210.52 receptacles shall be installed in 2' wall space
|
Rough-In Permanent Service | 5/19/2011 | 5/20/2011 | 5/20/2011 | P | NR |
Bob Reichert
|
|
|
Devon PLEASE CALL 30 MIN BEFORE GOING OUT Phone #: ###-#### met owner, no make-up done
|
ELE-Aging Inspection | 4/21/2011 | 4/21/2011 | 4/25/2011 | | DONE |
Bob Reichert
|
|
|
still under construction
|
Conference | 2/14/2011 | 2/15/2011 | 2/15/2011 | A | DONE |
Bob Reichert
|
|
|
DEVON Phone #: ###-#### reviewed wiring requirements for house
|