Final | 12/29/2011 | 12/30/2011 | 12/30/2011 | P | PASS |
Bob Reichert
|
|
|
Cal, Garage code 0813 Phone #: ###-#### >> Inspection requested via web by cal crosby ok final
|
Rough-In Permanent Service | 7/13/2011 | 7/13/2011 | 7/13/2011 | P | PASS |
Jack Frank
|
|
|
Cal Phone #: ###-#### >> Inspection requested via web by cal crosby called ,still needs to correct box fill, back door single gang switch box contractor said he will correct violation r/i p/s u/g new ok
|
Rough-In Permanent Service | 7/12/2011 | 7/12/2011 | 7/12/2011 | A | FAIL |
Jack Frank
|
|
|
Cal Phone #: ###-#### >> Inspection requested via web by cal crosby corr. & do not cover posted called box fill, outside boxes not flush with combustible material, 442.16(B)(4) range hood recept shall be on circuit all by itself protect all cables within 6ft of attic accesses, all recept outlet in laundry rm shall be on laundry circuit 314.17 NMB cable sheath shall extend into box 1/4", address nailplating and cables parallel
|