Final | 3/6/2012 | 3/7/2012 | 3/7/2012 | A | PASS |
Daryl DeGrange
|
|
|
matt Phone #: ###-#### corrections done final ok
|
Final | 2/28/2012 | 2/29/2012 | 2/29/2012 | P | FAIL |
Daryl DeGrange
|
|
|
max Phone #: ###-#### NEC 406.6 All receptacle shall be listed TR Tamper resistant type NEC 406.4 Boxes that set back 1/4 or more from inished surface shall have spark ring installed. Need to strap seal tight flex for A/C unit. Install all devices Furnace (switch) disconnect requires on/off labeled Can not install three wire receptacle in circuit without equipment ground or protect with GFCI device
|
Final | 2/23/2012 | 2/24/2012 | 2/24/2012 | A | NH |
Doug A Poedy
|
|
|
max Phone #: ###-####. Does not appear to be ready.
|
Rough-In Permanent Service | 8/22/2011 | 8/23/2011 | 8/23/2011 | P | PASS |
Daryl DeGrange
|
|
|
Please call 30min prior---max Phone #: ###-#### rough-in ps oh rec ok
|
Conference | 8/9/2011 | 8/10/2011 | 8/10/2011 | A | DONE |
Daryl DeGrange
|
|
|
call when on way//Max Phone #: ###-#### Discuss with home owner service locations, stapling, 1 /14 from from edge of framing member, smoke detector locations
|