Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberELE11-01867
StatusFinaled
Name TDR ELECTRIC
Site Address 5341 N MISTY RIDGE WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: New Residential
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/30/20121/30/20121/30/2012PPASS
DetailsJack Frank
Garage code 8607 Phone #: ###-#### >> Inspection requested via web by Therrin Robertson
Final1/26/20121/27/20121/27/2012AFAIL
DetailsJack Frank
Garage Code 8607 and 7373 Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called correction posted 314.3 metallic fitting not allowed in nonmetallic box, 314.43 screws not allowed in in plastic box, 314.20 box shall be flush with combustible material
Rough-In Permanent Service9/6/20119/6/20119/6/2011APASS
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson corrections made, ri ok, p/s u/g n ok
Rough-In Permanent Service9/1/20119/2/20119/2/2011AFAIL
DetailsBob Reichert
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called, left correction notice, NEC 334.23 shall protect cables within 6' of attic accesses, 362.30 shall secure ent within 3' of termination, 312.5 shall provide abrasion protection for cables in lv cabinet, 300.4(A) edge of hole shall be 1 14" from edge of framing member, or provide nailplate, BCC approved set of plans shall be on job