Permit Information
Permit NumberELE11-02138
StatusFinaled
Name ROBERTSON ELECTRIC
Site Address 4556 N VILLA RIDGE WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - New: Complete wiring of 2,937 square foot home
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/8/201112/9/201112/9/2011PPASS
DetailsDaryl DeGrange
Garage code is 6288 eneter Phone #: ###-#### >> Inspection requested via web by Zane Robertson final ok
Final12/6/201112/7/201112/7/2011PFAIL
DetailsDoug A Poedy
The garage code is 6288 enter Phone #: ###-#### >> Inspection requested via web by Zane Robertson. Garage doors not GFCI protected. No power for jetted tub in master.
Electrical Rough-In9/22/20119/23/20119/23/2011APASS
DetailsDaryl DeGrange
Phone #: ###-#### >> Inspection requested via web by Zane Robertson rough-in ok cover corections made
Rough-In Permanent Service9/21/20119/22/20119/22/2011ACANC
DetailsDoug A Poedy
Phone #: ###-#### >> Inspection requested via web by Zane Robertson
Electrical Rough-In9/22/20119/22/20119/22/2011AFAIL
DetailsDoug A Poedy
Phone #: ###-#### >> Inspection requested via web by Zane Robertson.NEC 210.52 D At least one receptacle shall be located within 3 ft of each basin. NEC 210.52 A2 Wall spacing. NEC 334.30 NM cable must be supported within 12 inches of a box.
Electrical Rough-In9/22/20119/22/20119/22/2011AFAIL
DetailsDoug A Poedy
Phone #: ###-#### >> Inspection requested via web by Zane Robertson. 210.52 Wall Spacing. 210.52 At least one receptacle within 3 ft of EACH basin. 334.30 NM cable needs to be supported within 12 inches.
Permanent Service9/22/20119/22/20119/22/2011APASS
DetailsDoug A Poedy
Phone #: ###-#### >> Inspection requested via web by Zane Robertson. P/S connect ok.