Final | 4/24/2014 | 4/25/2014 | 4/25/2014 | A | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### >> Inspection requested via web by cory carman final ok
|
Final | 4/24/2014 | 4/24/2014 | 4/24/2014 | P | FAIL |
Rex Boyles
|
|
|
Phone #: ###-#### >> Inspection requested via web by cory carman need one more GFCI in bsmt. bath receptacle
|
Final | 4/23/2014 | 4/23/2014 | 4/23/2014 | P | FAIL |
Rex Boyles
|
|
|
The key to the door is in meter box on back patio please put key back when finished thank you Phone #: ###-#### >> Inspection requested via web by cory carman 210.8(A)(1) bath receptacles need to be GFCI protected. 314.20- tile backsplash needs box extensions in bath and kitchen. 250.32- ground rod at garage panel. 250.53 (D)(2) add 2nd ground rod at house. 410.10(D) shower needs recessed trim rated for damp location. Install lockoffs on furnace and dishwasher breakers. garage u.ground conduit has no connector and needs to be strapped.
|
ELE-Aging Inspection | 3/20/2014 | 3/20/2014 | 3/20/2014 | | DONE |
Rex Boyles
|
|
|
left message for cory
|
ELE-Aging Inspection | 12/19/2013 | 12/19/2013 | 12/20/2013 | | CANC |
Rock A. Hudson
|
|
|
too busy
|
ELE-Aging Inspection | 9/19/2013 | 9/19/2013 | 9/19/2013 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 6/20/2013 | 6/20/2013 | 6/24/2013 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 3/21/2013 | 3/21/2013 | 3/21/2013 | | DONE |
Rock A. Hudson
|
|
|
drove by, still under construction
|
ELE-Aging Inspection | 12/20/2012 | 12/20/2012 | 12/20/2012 | | DONE |
Rock A. Hudson
|
|
|
Slow moving job. Still under construction
|
Electrical Rough-In | 12/20/2011 | 12/21/2011 | 12/21/2011 | A | PASS |
Daryl DeGrange
|
|
|
Please call Cory 30 minutes before so he can let you in the door as it is locked up Thank you Phone #: ###-#### >> Inspection requested via web by cory carman rough-in ok cover Electrical contractor agreed to add second ground rod
|