Permit Information
Permit NumberELE12-00222
StatusFinaled
Name CUSTOM ELECTRIC
Site Address 2076 S CENTURY WAY
Project Name 
Customer Number1068
ePlanReviewNo
Description
Electrical Permit - New: Remodel of existing warehouse
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/1/20125/2/20125/2/2012APASS
DetailsBob Reichert
Propane tanks in place. Project ready for final. Phone #: ###-#### >> Inspection requested via web by Todd Alder ok final, signed card
Final4/18/20124/18/20124/18/2012PPART
DetailsJack Frank
Temp occupancy inspection request - Building Dept has temp occupancy permit to sign. Engineer drawings for classified areas onsite. Phone #: ###-#### >> Inspection requested via web by Todd Alder
500.4 documentation ok T/O ok card signed
Final4/16/20124/16/20124/16/2012ANR
DetailsJack Frank
Inspection for temporary occupancy. Building Dept. has inspection card that needs signed. Phone #: ###-#### >> Inspection requested via web by Todd Alder
not raedy called needs too address panel covers, x-former grding see 250.30, also documentationfor classified areas 500.4 and seal all unused KOs
Final4/4/20124/5/20124/5/2012PNR
DetailsBob Reichert
Building Department has requested an electrical inspection for temp occupancy permit. Building is complete, but compressed gas and propane filling stations located outside building will be completed when occupant moves in. Building Department has requested onsite inspection card be signed for temp occupancy. Phone #: ###-#### >> Inspection requested via web by Todd Alder met contractor, still working on job
Electrical Rough-In3/13/20123/14/20123/14/2012PPASS
DetailsBob Reichert
Cover inspection for dropped ceiling. Onsite foreman - Shawn Wright ###-####. Phone #: ###-#### >> Inspection requested via web by Todd Alder ok cover ceiling
Electrical Rough-In2/29/20122/29/20122/29/2012PPASS
DetailsJack Frank
Cover inspection for conduits in trench. Depth adjusted under roadway and tank. Shawn onsite - ###-#### Phone #: ###-#### >> Inspection requested via web by Todd Alder ok voilation corrected
Electrical Rough-In2/27/20122/28/20122/28/2012PFAIL
DetailsBob Reichert
Cover inspection for underground conduit. Onsite - Shawn, ###-####. Phone #: ###-#### >> Inspection requested via web by Todd Alder called, conduit shall have minimum spacing and be 24" deep under tank and drive at west end building
Electrical Rough-In2/17/20122/17/20122/17/2012AFAIL
DetailsDoug A Poedy
Cover inspection for conduit in trench outside. Onsite foreman Matt Miller - ###-#### Phone #: ###-#### >> Inspection requested via web by Todd Alder. Needs to be 18 inches to top of pipe. Told it was ok to dig down farther then backfill leaving open 2 areas.
Electrical Rough-In2/2/20122/7/20122/7/2012APASS
DetailsBob Reichert
Rough-in Cover. Onsite foreman - Matt Miller - ###-#### Phone #: ###-#### >> Inspection requested via web by Todd Alder walls only inside ok cover, check on counter sales u/g since already poured, told contractor to provide area classification drawing as needed
Electrical Rough-In2/2/20122/6/20122/2/2012ACANC
DetailsJack Frank
Rough-in for cover. Matt Miller onsite foreman - ###-#### Phone #: ###-#### >> Inspection requested via web by Todd Alder Inspection cancelled from web by: Todd Alder