ELE-Aging Inspection | 3/15/2013 | 3/15/2013 | 3/15/2013 | | DONE |
Daryl DeGrange
|
|
|
see final
|
Final | 3/15/2013 | 3/15/2013 | 3/15/2013 | P | PASS |
Daryl DeGrange
|
|
|
job complete final ok
|
Electrical Rough-In | 2/29/2012 | 2/29/2012 | 2/29/2012 | P | CANC |
Bob Reichert
|
|
|
|
Electrical Rough-In | 2/29/2012 | 2/29/2012 | 2/29/2012 | P | PASS |
Bob Reichert
|
|
|
met with 445 and owner, items mentioned in conference notes taken care of, ok cover, will call for final when done
|
Conference | 2/29/2012 | 2/29/2012 | 2/29/2012 | P | DONE |
Doug A Poedy
|
|
|
|
Final | 2/17/2012 | 2/21/2012 | 2/21/2012 | A | FAIL |
Jack Frank
|
|
|
doug Phone #: ###-####same violations Bob told him about at conference owner said he is not going to fix violations, told him he will have to deal with Doug note free lenght, 250.32 needs 4wires for feeder, grd switches, staple cables within 8", needs main breaker, note remove devices from box so we can inspect splicing, note owner never called for r/i, job needs a complete r/i inspection
|
Conference | 2/3/2012 | 2/6/2012 | 2/6/2012 | A | DONE |
Bob Reichert
|
|
|
Douglas other phone number ###-#### Phone #: ###-#### building wired, too many violations to list, such as 3 wire feeder, no main, free conductor length, box fill, cable protection, called 414
|