Final | 5/9/2012 | 5/9/2012 | 5/9/2012 | A | PASS |
Doug A Poedy
|
|
|
Phone #: ###-#### >> Inspection requested via web by Greg Traudt
|
Final | 5/7/2012 | 5/7/2012 | 5/7/2012 | P | NR |
Jack Frank
|
|
|
Phone #: ###-#### >> Inspection requested via web by Greg Traudt check clearence closet fixtures 6" for flourescent, 12" for incandescent, 314.3 metal fittings in plastic boxes island counter, install M Bath light fixtures called
|
Electrical Rough-In | 4/9/2012 | 4/9/2012 | 4/9/2012 | P | PASS |
Bob Reichert
|
|
|
Greg Phone #: ###-#### ok cover floor heat
|
Rough-In Permanent Service | 2/28/2012 | 2/28/2012 | 2/28/2012 | P | PASS |
Jack Frank
|
|
|
Phone #: ###-#### >> Inspection requested via web by Greg Traudt p/s u/g new ok
|
Rough-In Permanent Service | 2/27/2012 | 2/27/2012 | 2/27/2012 | P | FAIL |
Jack Frank
|
|
|
Greg Phone #: ###-#### called left message corr. and do not cover posted, 250.24(A)(1) terminate GEC at neutral bus, 314.43 no nails allowed in plastic box outside front, 314.20 outside back box shall be flush with siding, 1103(A) replace broken switch box by pantry door, 334.23 protect romex within 6ft of attic accesses, 210.11(C)(2) address the 2 20 amp laundry circuits shall only feed recepts in laundry room, 250.148(C) grd all metal boxes
|