Final | 11/1/2012 | 11/2/2012 | 11/2/2012 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Final ok
|
Final | 10/31/2012 | 10/31/2012 | 10/31/2012 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI 1.Must have disconnect on upstairs furnace, 2. Light fixture located over shelf in upstairs closet/ furnace rm, 3. Front outdoor receptical must be weather resistant, 4. Vacuum receptical in garage must have GFCI protection, 5. Shop area off garage must have GFCI protection for recepticals, 6. Freezer receptical in garage must have GFCI protection, 7. All kitchen counter top recepticals must have GFCI protection, 8. Receptical in family room in-op, 9. Work clearance of 30" mustbe provided for AC disconnects, 10. White conductors used for phase conducors for ACs must be painted for entire length, 11. 30a breaker protecting 12 ga wire for AC.
|
Rough-In Permanent Service | 7/12/2012 | 7/12/2012 | 7/12/2012 | P | PASS |
Bob Reichert
|
|
|
New house Phone #: ###-#### >> Inspection requested via web by TOM BICANDI called, ri ok, p/s u/g n ok
|