Final | 12/14/2012 | 12/14/2012 | 12/14/2012 | P | PASS |
Rock A. Hudson
|
|
|
Jason is contact. Final for house addition. Phone #: ###-#### >> Inspection requested via web by Buster Bowen Final ok
|
Final | 12/12/2012 | 12/13/2012 | 12/13/2012 | P | FAIL |
Rock A. Hudson
|
|
|
Contact is Jason. Final on house addition. Phone #: ###-#### >> Inspection requested via web by Buster Bowen NEC 410.16(C) Incandescent luminaire shall be located a minimum of 12" from storage space or shelf. NEC 440.6 Ampacity of AC unit name plate rating 20 amp max. 30 amp breaker installed. NEC 406(B) Back patio receptical shall be weather resistant type.
|
Permanent Service | 9/21/2012 | 9/21/2012 | 9/21/2012 | P | PASS |
Rock A. Hudson
|
|
|
Jason in contact Phone #: ###-#### >> Inspection requested via web by Buster Bowen p/s u/g n ok Main breaker 10k rating
|
Electrical Rough-In | 9/11/2012 | 9/11/2012 | 9/11/2012 | P | PASS |
Doug A Poedy
|
|
|
Wall and ceiling cover. Phone #: ###-#### >> Inspection requested via web by Buster Bowen
|