Permit NumberELE13-00256
StatusFinaled
Name RYAN ERICKSON
Site Address 509 S ROOSEVELT ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/21/201610/21/201610/21/2016PPASS
DetailsEric Story
Ryan Phone #: ###-####
Correction fixed final ok
Final10/18/201610/19/201610/19/2016AFAIL
DetailsEric Story
Ryan-call for access Phone #: ###-####
210.8 GFCI shall be located in readily accessible location (gate will be changed to swing opposite direction so it wont hit meter)
Final8/9/20168/9/20168/9/2016PCANC
DetailsEric Story
Ryan Phone #: ###-####
not ready for final exposed romex will be be gaurded and all devices put in place, not meter was installed at this time, will clone a p/s only at this time
Permanent Service8/9/20168/9/20168/9/2016PPASS
DetailsEric Story
Ryan Phone #: ###-####
p/s o/h n ok
Final5/31/20166/1/20166/1/2016PFAIL
DetailsRock A. Hudson
Ryan Phone #: ###-####
210.8- All receptacles installed in residential garage shall have GFCI protection.
300.4- Where NM cable is ran through bored holes, Holes shall be 1 1/4" from each framing surface. Center holes in studs.
334.30- NM cable shall be secured with in 12" of boxes and panel.
406.12- All receptacle outlets installed in a residential garage shall be tamper resistant type.
Permanent Service6/1/20166/1/20166/1/2016PFAIL
DetailsRock A. Hudson
Ryan Phone #: ###-####
250.28- Main bonding jumper shall be installed to ground grounded conductor.
ELE-Aging Inspection4/7/20164/7/20164/8/2016 DONE
DetailsRex Boyles
too busy
ELE-Aging Inspection1/7/20161/7/20161/7/2016 DONE
DetailsRex Boyles
mailbox full could'nt leave message
ELE-Aging Inspection10/8/201510/8/201510/8/2015 DONE
DetailsRex Boyles
homeowner still working on this
Extend Permit 180 days7/9/20157/9/20157/9/2015PDONE
DetailsRex Boyles
Ryan Phone #: ###-#### did drive by to confirm service drop will satisfy 18 foot needed in alley ok
ELE-Aging Inspection6/9/20156/9/20156/9/2015 DONE
DetailsRex Boyles
too busy
ELE-Aging Inspection3/5/20153/5/20153/10/2015 DONE
DetailsRex Boyles
too busy
ELE-Aging Inspection12/4/201412/4/201412/5/2014 DONE
DetailsRex Boyles
left message for Ryan
Conference2/6/20132/7/20132/7/2013PDONE
DetailsDaryl DeGrange
Ryan-Please call at least 30 mins prior to inspection Phone #: ###-#### Discessed reqirement of new overhead service on unattach garage