Final | 10/21/2016 | 10/21/2016 | 10/21/2016 | P | PASS |
Eric Story
|
|
|
Ryan Phone #: ###-#### Correction fixed final ok
|
Final | 10/18/2016 | 10/19/2016 | 10/19/2016 | A | FAIL |
Eric Story
|
|
|
Ryan-call for access Phone #: ###-#### 210.8 GFCI shall be located in readily accessible location (gate will be changed to swing opposite direction so it wont hit meter)
|
Final | 8/9/2016 | 8/9/2016 | 8/9/2016 | P | CANC |
Eric Story
|
|
|
Ryan Phone #: ###-#### not ready for final exposed romex will be be gaurded and all devices put in place, not meter was installed at this time, will clone a p/s only at this time
|
Permanent Service | 8/9/2016 | 8/9/2016 | 8/9/2016 | P | PASS |
Eric Story
|
|
|
Ryan Phone #: ###-#### p/s o/h n ok
|
Final | 5/31/2016 | 6/1/2016 | 6/1/2016 | P | FAIL |
Rock A. Hudson
|
|
|
Ryan Phone #: ###-#### 210.8- All receptacles installed in residential garage shall have GFCI protection. 300.4- Where NM cable is ran through bored holes, Holes shall be 1 1/4" from each framing surface. Center holes in studs. 334.30- NM cable shall be secured with in 12" of boxes and panel. 406.12- All receptacle outlets installed in a residential garage shall be tamper resistant type.
|
Permanent Service | 6/1/2016 | 6/1/2016 | 6/1/2016 | P | FAIL |
Rock A. Hudson
|
|
|
Ryan Phone #: ###-#### 250.28- Main bonding jumper shall be installed to ground grounded conductor.
|
ELE-Aging Inspection | 4/7/2016 | 4/7/2016 | 4/8/2016 | | DONE |
Rex Boyles
|
|
|
too busy
|
ELE-Aging Inspection | 1/7/2016 | 1/7/2016 | 1/7/2016 | | DONE |
Rex Boyles
|
|
|
mailbox full could'nt leave message
|
ELE-Aging Inspection | 10/8/2015 | 10/8/2015 | 10/8/2015 | | DONE |
Rex Boyles
|
|
|
homeowner still working on this
|
Extend Permit 180 days | 7/9/2015 | 7/9/2015 | 7/9/2015 | P | DONE |
Rex Boyles
|
|
|
Ryan Phone #: ###-#### did drive by to confirm service drop will satisfy 18 foot needed in alley ok
|
ELE-Aging Inspection | 6/9/2015 | 6/9/2015 | 6/9/2015 | | DONE |
Rex Boyles
|
|
|
too busy
|
ELE-Aging Inspection | 3/5/2015 | 3/5/2015 | 3/10/2015 | | DONE |
Rex Boyles
|
|
|
too busy
|
ELE-Aging Inspection | 12/4/2014 | 12/4/2014 | 12/5/2014 | | DONE |
Rex Boyles
|
|
|
left message for Ryan
|
Conference | 2/6/2013 | 2/7/2013 | 2/7/2013 | P | DONE |
Daryl DeGrange
|
|
|
Ryan-Please call at least 30 mins prior to inspection Phone #: ###-#### Discessed reqirement of new overhead service on unattach garage
|