Final | 2/20/2015 | 2/20/2015 | 2/20/2015 | P | PASS |
Rex Boyles
|
|
|
Josh Phone #: ###-#### corrections made final ok
|
Final | 2/17/2015 | 2/17/2015 | 2/17/2015 | P | FAIL |
Rex Boyles
|
|
|
Josh Phone #: ###-#### 210.12-AFCI protection required on all bedroom circuits. 406.9(A)-a receptacle installed outdoors shall be a)GFCI protected and have an "extra heavy duty in use cover. 422.31-disconnection of permanently installed appliances shall have disconnect in sight of appliance or have lockoff on circuit breaker.
|
Permanent Service | 2/14/2014 | 2/14/2014 | 2/14/2014 | P | PASS |
Bob Reichert
|
|
|
Joshua Phone #: ###-#### p/s o/h n ok
|
Permanent Service | 2/12/2014 | 2/13/2014 | 2/13/2014 | P | FAIL |
Rock A. Hudson
|
|
|
JOSHUA Phone #: ###-#### 314.15- Conduit fitting shall be rated rain tight for outdoors to prevent water from entering.
|
Electrical Rough-In | 1/8/2014 | 1/8/2014 | 1/8/2014 | P | PASS |
Bob Reichert
|
|
|
josh - late afternoon please Phone #: ###-#### ri ok
|
Conference | 12/31/2013 | 12/31/2013 | 12/31/2013 | P | DONE |
Bob Reichert
|
|
|
Josh Phone #: ###-#### talked about progress on house
|
Conference | 12/23/2013 | 12/23/2013 | 12/23/2013 | P | DONE |
Bob Reichert
|
|
|
joshua Phone #: ###-#### talked about wiring new house, told to make ladder and upper level safe per OSHA rules
|