Final | 8/29/2013 | 8/30/2013 | 8/30/2013 | A | PASS |
Rock A. Hudson
|
|
|
brian Phone #: ###-#### Final ok
|
Final | 8/29/2013 | 8/29/2013 | 8/29/2013 | P | NH |
Rock A. Hudson
|
|
|
brian Phone #: ###-#### Dog barking, voices inside but no one would come to door
|
Electrical Rough-In | 5/7/2013 | 5/7/2013 | 5/7/2013 | P | PASS |
Rock A. Hudson
|
|
|
Brian Phone #: ###-#### Kitchen, family, bath, basement to remain unfinished. rough in ok cover
|
Electrical Rough-In | 5/6/2013 | 5/6/2013 | 5/6/2013 | P | FAIL |
Rock A. Hudson
|
|
|
brian Phone #: ###-#### 300.4(B)(2)- NMB cable shall be ran through holes that maintain 1 1/4" from surface of framing member if can not be maintained a nail plate shall protect. 300.4(D)- NMB cable shall maintain 1 1/4" from front of framing member when run down studs. 250.110- All non-current carrying metal parts shall be bonded.
|
Conference | 4/30/2013 | 4/30/2013 | 4/30/2013 | P | DONE |
Rock A. Hudson
|
|
|
request late pm//Brian Phone #: ###-#### Discussed code requirements for unfinished basements and unused wiring, terminations.
|