Final | 5/1/2014 | 5/2/2014 | 5/2/2014 | A | PASS |
Rock A. Hudson
|
|
|
>> Inspection requested via web by shane miller Final ok
|
Final | 4/30/2014 | 5/1/2014 | 5/1/2014 | A | FAIL |
Rock A. Hudson
|
|
|
Key has been left under door mat of each duplex door Phone #: ###-#### >> Inspection requested via web by shane miller 210.8- Kitchen GFCI will not trip itself. 410.16(C)(3)- Recessed incandescent lighting located in bed storage area shall have totally enclosed lamp
|
Electrical Rough-In | 8/12/2013 | 8/13/2013 | 8/13/2013 | A | PASS |
Bob Reichert
|
|
|
Front door will be openv Phone #: ###-#### >> Inspection requested via web by shane miller corrections made, ri ok
|
Electrical Rough-In | 8/8/2013 | 8/9/2013 | 8/9/2013 | A | FAIL |
Bob Reichert
|
|
|
Front door will be open Phone #: ###-#### >> Inspection requested via web by shane miller called, left message, shall provide nailplates, ground metal boxes, 1 1/4" for nm cable on studs, staple nm cable out of box, jacketing shall be minimum 1/4" in box, attic access shall protect cable within 6' of access
|
Electrical Rough-In | 6/17/2013 | 6/18/2013 | 6/18/2013 | A | FAIL |
Bob Reichert
|
|
|
house will be open for inspection wends Phone #: ###-#### >> Inspection requested via web by shane miller called, reviewed flush boxes, 6" free conductor, heaters,nailplates ground metal boxes, only 1 service drop to duplex, will recall
|