Final | 3/20/2014 | 3/21/2014 | 3/21/2014 | A | PASS |
Rex Boyles
|
|
|
Carl Phone #: ###-#### final ok corrections made
|
Final | 3/20/2014 | 3/20/2014 | 3/20/2014 | P | FAIL |
Bob Reichert
|
|
|
Darren Phone #: ###-#### called, corrections not all made, shall strap mc cable within 12" of fixtures where branch circuit, see NEC 330(30)(B) shall strap flex at heater, see NEC 348.30(A), shall provide gfci for washer within 6' of sink, see NEC 210.8(B)(5)
|
Final | 3/18/2014 | 3/19/2014 | 3/19/2014 | A | FAIL |
Bob Reichert
|
|
|
Contact is James Mair of Stock Construction. Call 30 minutes prior to arrival to ensure access to site. Phone #: ###-#### >> Inspection requested via web by Scott Campbell called contractor, too many items to write correction notice, told summarized here, shall add ko closures in panel,add receptacle covers, install panel cover, tighten boxes in wall by stove, provide gfci receptacles by stove,strap mc in ceiling,add kellum type grips to cord reel receptacles, add breaker blanks in old panel, correctly label old panel,provide gfci within 6' of sink for washer
|
Electrical Rough-In | 1/27/2014 | 1/27/2014 | 1/27/2014 | P | PASS |
Rock A. Hudson
|
|
|
Darren Phone #: ###-#### Bar wall rough in ok cover
|
Electrical Rough-In | 1/24/2014 | 1/27/2014 | 1/27/2014 | A | NH |
Bob Reichert
|
|
|
Contact is Carl Pettek Phone #: ###-#### >> Inspection requested via web by Scott Campbell called, locked up, will re-schedule
|
Electrical Rough-In | 11/25/2013 | 11/26/2013 | 11/26/2013 | A | PASS |
Rock A. Hudson
|
|
|
Contact is Carl Pettek Phone #: ###-#### >> Inspection requested via web by Scott Campbell Bar walls and soffit rough in ok cover
|
Electrical Rough-In | 11/6/2013 | 11/7/2013 | 11/7/2013 | P | PASS |
Rock A. Hudson
|
|
|
Underground - James Phone #: ###-#### Near bathroom rough in ok cover
|
Electrical Rough-In | 8/15/2013 | 8/16/2013 | 8/16/2013 | A | PASS |
Rock A. Hudson
|
|
|
Contact is TJ Proctor Phone #: ###-#### >> Inspection requested via web by Scott Campbell Bathrooms rough in ok cover
|
Electrical Rough-In | 7/17/2013 | 7/18/2013 | 7/18/2013 | P | PASS |
Rock A. Hudson
|
|
|
Underground inspection - contact is Dave Bradshaw ###-#### Phone #: ###-#### >> Inspection requested via web by Scott Campbell Interior underground rough in ok cover
|