Permit Information
Permit NumberELE13-02218
StatusFinaled
Name TRI STATE ELECTRIC
Site Address 7373 S FEDERAL WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - Alteration: Install meter main on pole then verify power for food truck
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
ELE-Aging Inspection3/17/20173/17/20173/20/2017 DONE
DetailsJames Ady
Finaled permit
Final3/20/20173/20/20173/20/2017PPASS
DetailsJames Ady
Food truck No long there. Permit final ok
ELE-Aging Inspection7/15/20167/15/20167/15/2016 CANC
DetailsBob Reichert
too busy
ELE-Aging Inspection4/5/20164/5/20164/6/2016 CANC
DetailsBob Reichert
too busy
Final1/8/20151/8/20151/8/2015PFAIL
DetailsRock A. Hudson
Contact: Brian Gee Phone #: ###-#### Inspection requested via web by Deb Gooden 406.8(A)- A receptacle installed in a wet location shall have an enclosure that is weatherproof with the attachment plug inserted or removed.
* No access to trailer to verify GFCI protection of 120 volt 15 or 20 amp receptical outlets and breaker blanks previously noted.
Permanent Service8/23/20138/23/20138/23/2013PPASS
DetailsBob Reichert
Contact: Darby Talbot Phone #: ###-#### >> Inspection requested via web by Deb Gooden will final when trailer done, p/s o/h n ok
Permanent Service8/22/20138/22/20138/22/2013AFAIL
DetailsBob Reichert
Contact: Jesse Phone #: ###-#### >> Inspection requested via web by Deb Gooden talked to contractor, shall provide fgci protection for cord connected trailer, shall fix trailer by strap riser, strap mc, provide breaker blanks, provide riser abrasion protection, strain relief for cord, cord shall be minimun #4 outdoor heavy duty, w rated, cord cap fixed, gfci protection
Final8/16/20138/16/20138/16/2013PNR
DetailsBob Reichert
Contact: Darby Talbot. Phone #: ###-#### >> Inspection requested via web by Deb Gooden called, contractor shall call for p/s, IPCO requires minimum 6"x6" pole, shall provide for inspection of food vendor for safety compliance and or listing, shall not use # 10 for service for food truck if 50A breaker in panel, shall identify breakers in panel