Final | 10/29/2013 | 10/30/2013 | 10/30/2013 | P | PASS |
Bob Reichert
|
|
|
Garage code 9045 Phone #: ###-#### >> Inspection requested via web by Neal Rumsey corrections made, ok final
|
Final | 10/28/2013 | 10/29/2013 | 10/29/2013 | A | FAIL |
Bob Reichert
|
|
|
garage code 9045 Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, left correction notice, NEC 406.8(B) outside receptacles shall be listed weather resistant type, 210.8(A)(3) outdoor receptacles shall be GFCI type
|
Rough-In Permanent Service | 9/16/2013 | 9/16/2013 | 9/16/2013 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey ri ok, p/s u/g n ok
|