Final | 1/29/2014 | 1/29/2014 | 1/29/2014 | A | PASS |
Rock A. Hudson
|
|
|
Final inspect at Jacksons. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Final ok
|
Final | 1/23/2014 | 1/23/2014 | 1/23/2014 | P | NR |
Bob Reichert
|
|
|
This is a Partial-final. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery still putting down tile, no access, still installing equipment, contractor to verify listing for walk-in coolers
|
Electrical Rough-In | 12/31/2013 | 12/31/2013 | 12/31/2013 | P | PASS |
Rock A. Hudson
|
|
|
Ceiling grid inspection for all areas with grid ceiling. Contact on job is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Ceiling rough in ok cover
|
Permanent Service | 12/4/2013 | 12/4/2013 | 12/4/2013 | A | PASS |
Rock A. Hudson
|
|
|
Service inspect. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery p/s u/g n ok
|
Electrical Rough-In | 11/27/2013 | 12/2/2013 | 12/2/2013 | A | CANC |
Rock A. Hudson
|
|
|
Rough inspection of new interior wall in the warehouse area. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Inspection cancelled from web by: Richard Montgomery
|
Electrical Rough-In | 11/27/2013 | 11/27/2013 | 11/27/2013 | P | PART |
Rock A. Hudson
|
|
|
Inspect for CT Can service, soffit in sales area and parking lot pole bases. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Pole bases and sales soffit rough in ok cover. Service 250.24(A)(1)- Grounding electrode conductor connection shall be made at an accessible point and shall terminate at the same bus bar or terminal as the grounded conductor.
|
Electrical Rough-In | 11/26/2013 | 11/27/2013 | 11/27/2013 | A | CANC |
Rock A. Hudson
|
|
|
Inspect for CT Can, soffit in sales area and parking lot pole bases. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Inspection cancelled from web by: Richard Montgomery
|
Electrical Rough-In | 11/21/2013 | 11/22/2013 | 11/22/2013 | A | PASS |
Rock A. Hudson
|
|
|
Ground inspection SE edge of property. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Perimeter underground to 3 pole lights and front compressor. rough in ok cover
|
Electrical Rough-In | 11/20/2013 | 11/20/2013 | 11/20/2013 | P | PASS |
Rock A. Hudson
|
|
|
Ceiling inspect for the restrooms. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Rough in ok cover
|
Electrical Rough-In | 11/19/2013 | 11/19/2013 | 11/19/2013 | A | PART |
Bob Reichert
|
|
|
Ground inspection. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery u/g except perimeter and island area ok cover, told ok cover entry with drive access only- about 10'
|
Electrical Rough-In | 11/18/2013 | 11/18/2013 | 11/18/2013 | P | PASS |
Daryl DeGrange
|
|
|
Interior walls rough-in. Contact on job is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in ok cover walls
|
Electrical Rough-In | 11/13/2013 | 11/14/2013 | 11/14/2013 | A | PASS |
Rock A. Hudson
|
|
|
Rough inspect exterior walls near coolers. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery South cooler wall rough in ok cover
|
Electrical Rough-In | 10/18/2013 | 10/21/2013 | 10/21/2013 | A | PASS |
Rock A. Hudson
|
|
|
Ground work inspection panel area only. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard MontgomeryUnderground from buiding service and control to pumps and misc. Rough in ok cover
|
Electrical Rough-In | 10/18/2013 | 10/18/2013 | 10/18/2013 | P | PART |
Rock A. Hudson
|
|
|
Interior underground inspection. Contact on the job is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery 514.9- All conduits that run to or through hazardous locations shall have seals at both ends. Non metalloc conduits ok 2' and deeper. Where conduit is less than 2' it shall be rigid or IMC. Rough in central area ok cover.
|
Electrical Rough-In | 10/8/2013 | 10/9/2013 | 10/9/2013 | A | PASS |
Rock A. Hudson
|
|
|
This is an inspect for the uffer ground. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Rough in ok cover
|