DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/10/201411/10/201411/10/2014PPASS
DetailsRock A. Hudson
Don// please call before Phone #: ###-#### Final ok
Final11/3/201411/4/201411/4/2014ANH
DetailsRock A. Hudson
Don Phone #: ###-####// please call before Gave 25 minutes notice no return call. no answer at door left card
Final2/11/20142/12/20142/12/2014PFAIL
DetailsRock A. Hudson
Donald PLEASE call before going out Phone #: ###-#### All receptical outlets shall be tamper resistant type.
Type UF cable shall be protected from physical damage.
All bed outlets shall be AFCI protected. LT and switch.
Reverse polarity in bed
Final12/23/201312/24/201312/24/2013PFAIL
DetailsRock A. Hudson
Donald Phone #: ###-#### 408.4- Every circuit shall be legibly identified.
406.8(B)- 15 and 20 amp 120 volt receptical outlets installed outdoors shall be weather resistant type.
210.8- All 15 and 20 amp receptical outlets installed outside shall have GFCI protection.
110.3(B)- Devices not installed as per manufactureds instructions, GFI outlet lin/ load reversed, and reversed polarity, dead outlets.
210.8- receptical outlets installed to serve counter top in kitchen shall have GFCI protection.
314.25- All boxes shall have covers.
210.11(C)(3)- Bathroom recepticals shall be installed on a 20 amp circuit and shall not feed other outlets.
300.4- NM cable in garage shall not be secured less than 1 1/4" from framing surface.
340.12(10)- Type UF cable shall not be installed where subject to physical damage.
210.8- Garage 15 and 20 amp recepticals shall have GFCI protection.
Final12/18/201312/19/201312/19/2013PNR
DetailsRock A. Hudson
Donald Phone #: ###-#### Junction boxes still being installed, Circuits cold and covers missing.
Permanent Service12/18/201312/19/201312/19/2013APASS
DetailsRock A. Hudson
DON (SET FOR 8 AM PER ROCK) Phone #: ###-#### p/s o/h rec ok
Electrical Rough-In11/8/201311/12/201311/12/2013APASS
DetailsRock A. Hudson
###-#### RI ok
Electrical Rough-In11/6/201311/8/201311/8/2013PPASS
DetailsRock A. Hudson
Don Phone #: ###-#### wall and ceiling rough in ok cover
Electrical Rough-In11/1/201311/6/201311/6/2013ACANC
DetailsRock A. Hudson
Don Phone #: ###-#### 11-6-13 per Donald May cancel this inspection not ready
Conference10/15/201310/16/201310/16/2013PDONE
DetailsRock A. Hudson
Don Phone #: ###-#### Discussed code requirements for rewiring house and garage