Final | 11/10/2014 | 11/10/2014 | 11/10/2014 | P | PASS |
Rock A. Hudson
|
|
|
Don// please call before Phone #: ###-#### Final ok
|
Final | 11/3/2014 | 11/4/2014 | 11/4/2014 | A | NH |
Rock A. Hudson
|
|
|
Don Phone #: ###-####// please call before Gave 25 minutes notice no return call. no answer at door left card
|
Final | 2/11/2014 | 2/12/2014 | 2/12/2014 | P | FAIL |
Rock A. Hudson
|
|
|
Donald PLEASE call before going out Phone #: ###-#### All receptical outlets shall be tamper resistant type. Type UF cable shall be protected from physical damage. All bed outlets shall be AFCI protected. LT and switch. Reverse polarity in bed
|
Final | 12/23/2013 | 12/24/2013 | 12/24/2013 | P | FAIL |
Rock A. Hudson
|
|
|
Donald Phone #: ###-#### 408.4- Every circuit shall be legibly identified. 406.8(B)- 15 and 20 amp 120 volt receptical outlets installed outdoors shall be weather resistant type. 210.8- All 15 and 20 amp receptical outlets installed outside shall have GFCI protection. 110.3(B)- Devices not installed as per manufactureds instructions, GFI outlet lin/ load reversed, and reversed polarity, dead outlets. 210.8- receptical outlets installed to serve counter top in kitchen shall have GFCI protection. 314.25- All boxes shall have covers. 210.11(C)(3)- Bathroom recepticals shall be installed on a 20 amp circuit and shall not feed other outlets. 300.4- NM cable in garage shall not be secured less than 1 1/4" from framing surface. 340.12(10)- Type UF cable shall not be installed where subject to physical damage. 210.8- Garage 15 and 20 amp recepticals shall have GFCI protection.
|
Final | 12/18/2013 | 12/19/2013 | 12/19/2013 | P | NR |
Rock A. Hudson
|
|
|
Donald Phone #: ###-#### Junction boxes still being installed, Circuits cold and covers missing.
|
Permanent Service | 12/18/2013 | 12/19/2013 | 12/19/2013 | A | PASS |
Rock A. Hudson
|
|
|
DON (SET FOR 8 AM PER ROCK) Phone #: ###-#### p/s o/h rec ok
|
Electrical Rough-In | 11/8/2013 | 11/12/2013 | 11/12/2013 | A | PASS |
Rock A. Hudson
|
|
|
###-#### RI ok
|
Electrical Rough-In | 11/6/2013 | 11/8/2013 | 11/8/2013 | P | PASS |
Rock A. Hudson
|
|
|
Don Phone #: ###-#### wall and ceiling rough in ok cover
|
Electrical Rough-In | 11/1/2013 | 11/6/2013 | 11/6/2013 | A | CANC |
Rock A. Hudson
|
|
|
Don Phone #: ###-#### 11-6-13 per Donald May cancel this inspection not ready
|
Conference | 10/15/2013 | 10/16/2013 | 10/16/2013 | P | DONE |
Rock A. Hudson
|
|
|
Don Phone #: ###-#### Discussed code requirements for rewiring house and garage
|