Final | 6/17/2014 | 6/18/2014 | 6/18/2014 | A | PASS |
Rock A. Hudson
|
|
|
0505enter Phone #: ###-#### >> Inspection requested via web by Dan Rohl Final ok
|
Final | 6/11/2014 | 6/11/2014 | 6/12/2014 | P | FAIL |
Bob Reichert
|
|
|
Code 0505 enter Phone #: ###-#### >> Inspection requested via web by Dan Rohl see 2/12 response
|
Final | 6/12/2014 | 6/12/2014 | 6/12/2014 | A | FAIL |
Bob Reichert
|
|
|
Dan ###-#### called, left correction notice, NEC 210.52(C)(1) countertop shall have receptacle such that no point over 24" from receptacle, 210.52(D) bath receptacle shall be within 3' of edge of sink, 400.8 so cord shall not be used for permanent wiring, 314.23 shall securely mount box in kitchen, 422.11 shall provide overcurrent protection for a/c per nameplate, BCC shall provide 50% energy efficient bulbs
|
Rough-In Permanent Service | 10/31/2013 | 11/1/2013 | 11/1/2013 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Rohl rough in ok cover p/s u/g n ok
|