Final | 5/10/2014 | 5/12/2014 | 5/12/2014 | A | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson final ok
|
Final | 5/9/2014 | 5/9/2014 | 5/9/2014 | P | FAIL |
Rex Boyles
|
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson call when ready open nuetral in kit. counter, no access to basement
|
Rough-In Permanent Service | 1/24/2014 | 1/24/2014 | 1/24/2014 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 1/23/2014 | 1/23/2014 | 1/23/2014 | P | FAIL |
Rock A. Hudson
|
|
|
334.30- NM cable shall be supported at intervals not to exceed 4 1/2', NM cable shall be secured within 12" of boxes. lower stair cans, stair light, garage. 314.17- NM sheathing shall enter box minimum of 1/4". J-box by garage door
|