Final | 8/5/2014 | 8/5/2014 | 8/5/2014 | P | PASS |
Rex Boyles
|
|
|
Josh is contact. Thank u Phone #: ###-#### Inspection requested via web by Chris Chesnut final ok
|
Final | 8/4/2014 | 8/4/2014 | 8/4/2014 | P | NR |
Rex Boyles
|
|
|
Josh is contact thank you Phone #: ###-#### Inspection requested via web by Chris Chesnut corrections made but no access to upst. stairs wet with finish
|
Final | 8/1/2014 | 8/1/2014 | 8/1/2014 | P | FAIL |
Rex Boyles
|
|
|
Josh is contact Phone #: ###-#### Inspection requested via web by Chris Chesnut 210.8 (A)(2) -garage outlets all need GFCI protection, 314.20-no more than 1/4" from finish surface to front edge of box(kitchen backsplash, 422.31- lockofss on cir. breakers for microwave and dbl. oven, loose kitchen counter recetacle, 2" strap on meter base conduit, dnst. laundry room has GFCI on GFCI from upst. bath
|
Electrical Rough-In | 5/29/2014 | 5/30/2014 | 5/30/2014 | A | PASS |
Rock A. Hudson
|
|
|
Josh is contact. Step lights going up to front door is all I''m having inspected. Thank you! Phone #: ###-#### >> Inspection requested via web by Chris Chesnut Front step light rough in ok cover
|
Rough-In Permanent Service | 5/7/2014 | 5/8/2014 | 5/8/2014 | A | PASS |
Bob Reichert
|
|
|
Chris is contact. CAN YOU PLEASE CALL 30 MINUTES BEFORE YOU HEAD THERE? If at all possible. Thanks! Phone #: ###-#### >> Inspection requested via web by Chris Chesnut ri ok except front steps area, p/s u/g n ok
|
Rough-In Permanent Service | 5/7/2014 | 5/7/2014 | 5/7/2014 | P | NR |
Bob Reichert
|
|
|
Thank you! Chris is contact Phone #: ###-#### >> Inspection requested via web by Chris Chesnut called, too many violations to list such as outlet spacing,w iring in pinch points of beams, nm stapled on edge, framing not done for stairs, outside wiring not in box by stairs, will recheck and recall
|
Electrical Rough-In | 5/6/2014 | 5/6/2014 | 5/6/2014 | P | PASS |
Rex Boyles
|
|
|
Soffit inspection is all. Chris is contact. Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut rough in exterior soffit can lights ok to cover
|