Permit Information
Permit NumberELE14-00437
StatusFinaled
Name RICHTSMEIER DEAN J
Site Address 5222 W WYLIE LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Permit to re-wire 5 rooms
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final11/4/201411/5/201411/5/2014APASS
DetailsCevyn Recla
FInal OK
Final11/3/201411/5/201411/4/2014ANR
DetailsCevyn Recla
Erin Phone #: ###-####
left message with owner, not ready
Final11/3/201411/3/201411/3/2014PFAIL
DetailsCevyn Recla
110.12A Unused openings shall be closed


Grounding receptacle and cord required for range
Spoke with owner
Final11/3/201411/3/201411/3/2014PNH
DetailsCevyn Recla
Erin Phone #: ###-####
Left message, nobody home, no access
Electrical Rough-In3/24/20143/25/20143/25/2014APASS
DetailsRock A. Hudson
erin Phone #: ###-#### Not all walls accessible. rough in ok cover
Permanent Service3/13/20143/13/20143/13/2014PPASS
DetailsRock A. Hudson
As early as possible-Erin--Please call at least 30 mins prior to inspection Phone #: ###-####
p/s o/h rec ok
Permanent Service3/11/20143/12/20143/12/2014AFAIL
DetailsRock A. Hudson
Erin or Dean-Please call at least 30 mins in advance of inspection Phone #: 412- 0527
230.28- Where service mast is used as support for overhead swing and it extends 3' or more past its support it shall have additional support.
250.90(B)- Metal nipple ran through concentric knockout shall have bonding bushing.
Conference2/24/20142/27/20142/27/2014PDONE
DetailsRock A. Hudson
dean - call 30 mins prior Phone #: ###-#### Discussed required recepticals locations around habitable rooms, 1 1/4" rule ith securing and bored holes, main breaker will be required for service.