DOC - Permit Expired | 2/1/2019 | 2/1/2019 | 2/1/2019 | P | PASS |
Daryl DeGrange
|
|
|
No activity within 180 days. This permit is EXPIRED. A new permit is required to complete this job.
|
ELE-Aging Inspection | 1/17/2019 | 1/17/2019 | 1/17/2019 | | DONE |
Tom Saunders
|
|
|
contact has been made... still waiting
|
ELE-Aging Inspection | 10/5/2018 | 10/5/2018 | 10/9/2018 | | FAIL |
Tom Saunders
|
|
|
have made contact...waiting on permit holder
|
ELE-Aging Inspection | 6/1/2018 | 6/1/2018 | 6/4/2018 | | PASS |
Tom Saunders
|
|
|
left message on contacts voicemail...requesting to get in contact with Boise City PDS or me to get permit finaled and closed
|
Final | 11/6/2014 | 11/7/2014 | 11/7/2014 | P | FAIL |
Rock A. Hudson
|
|
|
Robert Phone #: ###-#### All receptical outlets install in garage shall be tamper resistanr type. Recepticla outlet shall be a minimum of 6' from hot tub
|
Electrical Rough-In | 9/4/2014 | 9/4/2014 | 9/4/2014 | P | PASS |
Rock A. Hudson
|
|
|
Robert Phone #: ###-#### Garage Rough in ok cover
|
ELE-Request for Extension | 8/26/2014 | 8/26/2014 | 8/26/2014 | A | DONE |
Daryl DeGrange
|
|
|
Extension of permit ok
|
Electrical Rough-In | 8/22/2014 | 8/22/2014 | 8/22/2014 | P | FAIL |
Rock A. Hudson
|
|
|
Robert Phone #: ###-#### 230.79- Detached garage with more than 2 circuits shall have 60 amp feed minimum. Detached garage shall have disconnecting means. Conductors feeding haot tub shall be of sufficient size. 334.30 NM cable shall be secured with in 8" of box with open entry.
|
Electrical Rough-In | 4/17/2014 | 4/18/2014 | 4/18/2014 | A | PASS |
Rock A. Hudson
|
|
|
Robert-underground Phone #: ###-#### Underground from house to garage rough in ok cover
|