Final | 5/19/2014 | 5/20/2014 | 5/20/2014 | A | PASS |
Rex Boyles
|
|
|
Mark Phone #: ###-#### final ok
|
Final | 5/15/2014 | 5/15/2014 | 5/15/2014 | P | FAIL |
Rex Boyles
|
|
|
Mark Phone #: ###-#### shower trim needed for upst. shower for wet location. box extensions needed for kitchen backsplash where box is more than 1/4" to finish surface. flexable conduit to a/c not rated for wet location. Identify garage disconnect switch as disconnect. Need 50 % energy saving lamps as per boise municipal code, fix loose receptacles, nm cable in island needs to be protected from phisical damage
|
Permanent Service | 3/10/2014 | 3/10/2014 | 3/10/2014 | P | PASS |
Rex Boyles
|
|
|
mark Phone #: ###-#### p/s u/g n ok
|
Electrical Rough-In | 3/7/2014 | 3/10/2014 | 3/10/2014 | A | PASS |
Rex Boyles
|
|
|
mark Phone #: ###-#### rough in ok on house and garage and underground to garage
|