Final | 6/18/2014 | 6/18/2014 | 6/18/2014 | P | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin job complete, final ok
|
Electrical Rough-In | 6/11/2014 | 6/11/2014 | 6/11/2014 | P | PASS |
Daryl DeGrange
|
|
|
drop in ceiling Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin rough-in ok cover ceiling grid back storage and office rooms
|
Electrical Rough-In | 6/4/2014 | 6/4/2014 | 6/4/2014 | P | PASS |
Daryl DeGrange
|
|
|
Correction to kiosk conduits Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin correction done, rough-in ok cover
|
Electrical Rough-In | 5/7/2014 | 5/7/2014 | 5/7/2014 | P | PASS |
Daryl DeGrange
|
|
|
ceiling Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin rough-in ok cover ceiling Beauty room #6 and rear entry hallway
|
Electrical Rough-In | 5/5/2014 | 5/5/2014 | 5/5/2014 | P | PASS |
Daryl DeGrange
|
|
|
ceiing Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Rough-in ok cover ceiling of West store front entry.
|
Electrical Rough-In | 5/5/2014 | 5/5/2014 | 5/5/2014 | P | FAIL |
Daryl DeGrange
|
|
|
ceiing Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Exposed conduits traveling down column in store front entry, broken and internal diameter of the conduit has been reduced. Depth of conduit NEC 300.5
|
Electrical Rough-In | 5/5/2014 | 5/5/2014 | 5/5/2014 | P | FAIL |
Daryl DeGrange
|
|
|
ceiing Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Exposed PVC conduits in store front entry NEC 352.24 Internal diameter of the conduits have been reduced when relocated. NEC 300.5 Depth of conduits encased in concrete
|
Electrical Rough-In | 5/1/2014 | 5/1/2014 | 5/1/2014 | P | PASS |
Daryl DeGrange
|
|
|
ceiling Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Rough-in ok cover ceiling grid VSL 2
|
Electrical Rough-In | 4/30/2014 | 4/30/2014 | 4/30/2014 | P | PASS |
Daryl DeGrange
|
|
|
ceiling Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin rough-in ok cover VSL room ceiling grid
|
Electrical Rough-In | 4/29/2014 | 4/29/2014 | 4/29/2014 | P | PASS |
Daryl DeGrange
|
|
|
ceiling Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Rough-in ok cover ceiling grid (Bra salon)
|
Electrical Rough-In | 4/28/2014 | 4/28/2014 | 4/28/2014 | P | PASS |
Daryl DeGrange
|
|
|
ceiling Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin rough-in ok cover pink rooms 1&2
|
Electrical Rough-In | 4/21/2014 | 4/21/2014 | 4/21/2014 | P | PASS |
Rock A. Hudson
|
|
|
Walls Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Front are soffit and interior walls rough in ok cover
|
Electrical Rough-In | 4/15/2014 | 4/15/2014 | 4/15/2014 | P | PASS |
Daryl DeGrange
|
|
|
walls Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin rough-in ok cover middle section (third)walls
|
Electrical Rough-In | 4/11/2014 | 4/11/2014 | 4/11/2014 | P | PART |
Daryl DeGrange
|
|
|
Partial wall, before 2pm if possible please Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Rough-in ok cover rear third walls only
|
Permanent Service | 4/7/2014 | 4/7/2014 | 4/7/2014 | P | PASS |
Rock A. Hudson
|
|
|
partial wall Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Building steel bonded need check plumbing due to main water moving. p/s u/g n ok
|
Electrical Rough-In | 4/4/2014 | 4/7/2014 | 4/7/2014 | A | PART |
Rock A. Hudson
|
|
|
partial wall Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Back bathroom, office and break room wall rough in ok cover
|
Electrical Rough-In | 3/25/2014 | 3/26/2014 | 3/26/2014 | A | PASS |
Daryl DeGrange
|
|
|
underground Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin Rough-in ok cover 7 CSA listed floor receptacles
|