Final | 10/7/2014 | 10/8/2014 | 10/8/2014 | A | PASS |
Rex Boyles
|
|
|
Tyler Phone #: ###-#### all corrections made final ok
|
Final | 10/6/2014 | 10/7/2014 | 10/7/2014 | A | FAIL |
Rex Boyles
|
|
|
Tyler Phone #: ###-#### 210.8(A) all 15 and 20 amp receptacles above kitchen countertops shall be GFCI protected.(kitchen and wet bar upst.) 314,20-all outlet boxes shall be 1/4 inch or less from finish surface to face of box.(box extensions needed). lockoffs required for kitchen hood and dishwasher and water heater. 210.12(A)-AFCI protection required for all bedrooms. 406.9(A)-All outside 15 and 20 amp receptacles require weather resistant receptacles. Disconnect switch required at furnace in attic. A/C condensing unit wiring on load side needs to be rated to use outdoors or type "thwn". Install correct "maximum fuse " size for condensing unit. 400.8-120 volt hockey puck fixture cords not permitted to run through cabinets and open splice not allowed. Strap 1 inch conduit feeding garage within 3 foot of termination.
|
Electrical Rough-In | 7/9/2014 | 7/9/2014 | 7/9/2014 | P | PASS |
Rex Boyles
|
|
|
Tyler Phone #: ###-#### r/i ok house and garage
|
Electrical Rough-In | 6/23/2014 | 6/23/2014 | 6/23/2014 | P | PASS |
Rex Boyles
|
|
|
Trench inspection-Tyler Phone #: ###-#### kitchen u. g. ok to cover
|
Electrical Rough-In | 6/10/2014 | 6/11/2014 | 6/11/2014 | A | CANC |
Rex Boyles
|
|
|
Tyler Phone #: ###-#### needed p/s
|
Permanent Service | 6/11/2014 | 6/11/2014 | 6/11/2014 | P | PASS |
Rex Boyles
|
|
|
Tyler Phone #: ###-#### p/s o/h n ok
|
Rough-In Permanent Service | 3/28/2014 | 3/28/2014 | 3/28/2014 | P | CANC |
Rex Boyles
|
|
|
Tyler Phone #: ###-#### needed temp. serv
|
Temporary Service | 3/28/2014 | 3/28/2014 | 3/28/2014 | P | PASS |
Rex Boyles
|
|
|
Tyler Phone #: ###-#### t/s o/h n ok use existing drop from old house
|
Rough-In Permanent Service | 3/27/2014 | 3/28/2014 | 3/28/2014 | A | NR |
Rex Boyles
|
|
|
call for access about 30minutes - Tyler Phone #: ###-#### not ready
|