Final | 4/14/2014 | 4/15/2014 | 4/15/2014 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Surerus Platform in place for work space. Final ok
|
Final | 4/9/2014 | 4/10/2014 | 4/10/2014 | P | FAIL |
Rock A. Hudson
|
|
|
Place is unoccupied. Go thru back yard and in the sliding glass door. Phone #: ###-#### >> Inspection requested via web by Dan Surerus 110.26(A)(1)(A)- Dedicated electrical space equal to the depth and width of electrical equiptment shall be clear of ducts, pipes, and other equiptment from floor to ceiling. 110.26- Due to duct work below panel unstable work platform exists.
|