Final | 10/1/2014 | 10/3/2014 | 10/3/2014 | A | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### Inspection requested via web by Eddy Udry corrections made final ok
|
Final | 10/1/2014 | 10/1/2014 | 10/1/2014 | P | FAIL |
Daryl DeGrange
|
|
|
Please call so we can get you in. Thanks Eddy ###-#### Phone #: ###-#### Inspection requested via web by Eddy Udry NEC 406.8(B)(1) Front outside receptacles requires WR device.Washer receptaccle within 6ft. of sink require GFCI. Master bath vanity receptacle requires GFCI protection.Aluminum flex on A/C unit replace with LFNC.Install photo cell for garage lights
|
Electrical Rough-In | 5/5/2014 | 5/5/2014 | 5/5/2014 | P | PASS |
Daryl DeGrange
|
|
|
Phone #: ###-#### >> Inspection requested via web by Eddy Udry correction done, rough-in ok cover House and garage
|
Electrical Rough-In | 5/2/2014 | 5/5/2014 | 5/5/2014 | A | FAIL |
Daryl DeGrange
|
|
|
eddy Phone #: ###-#### NEC 300.4 nail plates. NEC 334.30 stapling. missing mudrings, under stairs and in garage for concrete encased electrode
|
Electrical Rough-In | 5/2/2014 | 5/2/2014 | 5/2/2014 | P | CANC |
Rex Boyles
|
|
|
If there is any way to do this late afternoon that would be great. Thanks Eddy Phone #: ###-#### >> Inspection requested via web by Eddy Udry cancelled till monday
|
Permanent Service | 4/15/2014 | 4/15/2014 | 4/15/2014 | P | PASS |
Rex Boyles
|
|
|
Phone #: ###-#### >> Inspection requested via web by Eddy Udry p/s o/h n ok
|