Final | 9/19/2014 | 9/19/2014 | 9/19/2014 | P | PASS |
Rock A. Hudson
|
|
|
code 1998 Phone #: ###-#### Inspection requested via web by cal crosby Final ok
|
Final | 9/18/2014 | 9/18/2014 | 9/18/2014 | P | FAIL |
Rock A. Hudson
|
|
|
code 1998, if needed box is on side door Phone #: ###-#### Inspection requested via web by cal crosby 356.30 Securing and Supporting. Type LFNC-B shall be securely fastened and supported in accordance with one of the following: (1) Where installed in lengths exceeding 1.8 m (6 ft), the conduit shall be securely fastened at intervals not exceeding 900 mm (3 ft) and within 300 mm (12 in.) on each side of every outlet box, junction box, cabinet, or fitting. AC whip. 200.7(C) Circuits of 50 Volts or More. The use of insulation that is white or gray or that has three continuous white or gray stripes for other than a grounded conductor for circuits of 50 volts or more shall be permitted only as in (1) and (2). (1) If part of a cable assembly that has the insulation permanently reidentified to indicate its use as an ungrounded conductor by marking tape, painting, or other effective means at its termination and at each location where the conductor is visible and accessible. 440.4 Marking on Hermetic Refrigerant Motor- Compressors and Equipment. (C) Branch-Circuit Selection Current. A hermetic refrigerant motor-compressor, or equipment containing such a compressor, having a protection system that is approved for use with the motor-compressor that it protects and that permits continuous current in excess of the specified percentage of nameplate rated-load current given in 440.52(B)(2) or (B)(4) shall also be marked with a branch-circuit selection current that complies with 440.52(B)(2) or (B)(4). This marking shall be provided by the equipment manufacturer and shall be on the nameplate(s) where the rated-load current( s) appears. 110.12 Mechanical Execution of Work. Electrical equipment shall be installed in a neat and workmanlike manner. Informational Note: Accepted industry practices are described in ANSI/NECA 1-2010, Standard Practice of Good Workmanship in Electrical Construction, and other ANSIapproved installation standards. (A) Unused Openings. Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or those permitted as part of the design for listed equipment, shall be closed.
|
Electrical Rough-In | 6/5/2014 | 6/5/2014 | 6/5/2014 | A | PASS |
Rock A. Hudson
|
|
|
Code in lock box on front door # 3536 Phone #: ###-#### >> Inspection requested via web by cal crosby Rough in ok cover
|