Final | 9/11/2014 | 9/12/2014 | 9/12/2014 | A | PASS |
Bob Reichert
|
|
|
Autocover switch on west fence. Autocover code = 1583. Phone #: ###-#### Inspection requested via web by Lars Johnson ok final
|
Electrical Rough-In | 8/27/2014 | 8/28/2014 | 8/28/2014 | A | PASS |
Bob Reichert
|
|
|
Spa light potting compound Phone #: ###-#### >> Inspection requested via web by Lars Johnson spa light potting ok
|
Electrical Rough-In | 7/31/2014 | 7/31/2014 | 7/31/2014 | P | PASS |
Bob Reichert
|
|
|
- removing 90 degree from home run conduit to get to 360 - getting low voltage light conduits to 18" as close to pool edge as possible (5'' concrete deck around pool) - white pvc conduit sleeves entering pool are part of low voltage lighting assembly Phone #: ###-#### >> Inspection requested via web by Lars Johnson corrections made, ok cover u/g
|
Electrical Rough-In | 7/28/2014 | 7/29/2014 | 7/29/2014 | A | FAIL |
Bob Reichert
|
|
|
swimming pool and spa electrical remaining underground and bonding Phone #: ###-#### >> Inspection requested via web by Lars Johnson called, left correction notice, NEC 680.10 pvc shall be minimum 18" deep within 5 ' of pool, 352.26 there shall not be over 360 degree total bend in raceway, 110.3(A)(B) pvc shall not be used with non-labelled raceway system
|
Final | 7/9/2014 | 7/10/2014 | 7/10/2014 | A | PASS |
Rex Boyles
|
|
|
Partial underground & bonding Phone #: ###-#### >> Inspection requested via web by Lars Johnson r/i ok bonding pool cover and spa light
|