Permit Information
Permit NumberELE14-01896
StatusFinaled
Name R M E INC
Site Address 2815 W PLEASANTON AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Electrical Permit - Addition: Install dryer outlets and power to split systmes
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/12/20155/13/20155/13/2015APASS
DetailsDaryl DeGrange
Please Call Matt ###-#### 1/2 prior to arrival. Phone #: ###-#### Inspection requested via web by Buster Bowen Job complete, final ok
Final4/6/20154/7/20154/7/2015AFAIL
DetailsDaryl DeGrange
Matt Foster is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen NEC 334.12(B)(4) NM shall not be installed in wet or damp locations, wiring for mini split systems.
Electrical Rough-In9/23/20149/24/20149/24/2014APASS
DetailsRex Boyles
Matt. Bottom apartment dryer circuit. Phone #: ###-#### Inspection requested via web by Sean DeLacy r/i ok unit C dryer outlet
Electrical Rough-In8/27/20148/28/20148/28/2014PPASS
DetailsRex Boyles
Matt. Can you call half hour prior to heading towards site. Phone #: ###-#### Inspection requested via web by Sean DeLacy r/i ok for water heater circuit and washer dryer circuits and mini split power and controls for units A,B,C and D also remove bonding screws in loadcenters before final insp.
Electrical Rough-In8/11/20148/12/20148/12/2014PFAIL
DetailsDaryl DeGrange
Matt. Phone #: ###-#### Inspection requested via web by Sean DeLacy NEC 230.24(A) ex3 Clearance of 18in. of service conductors above overhang portion of roof NEC 240.24(D) (Service panel) Over current devices shall not be located in the vcinity of easily ignitible material, such as clothes closets, BCC 04-05-31 A panel location shall not be installed in a unsafe location